The revolutionary switching technology utilized in the Aurora inverter includes state of the art silicon Power Devices such as CoolMOSTM and Gate Bi-polar Transistors (IGBT's) to reduce switching losses.
Aurora has been designed with large de-rating criteria on all critical components, achieving an extremely robust and reliable inverter designed to last for 25 years and to deliver true maximum output power on a continuous basis. With this design concept we achieve peak efficiencies of over 97%. Total current harmonic distortion, on the other hand, is typically less than 1% through the use of high-frequency switching techniques. Another exclusive advantage is Aurora's two source circuit inputs, each with its own MPPT (Max Power Point Tracker) for installations and multiple arrays.
 |
Benefits
- PMG (Permanent Magnet Generator) Power Curve implemented in high speed MPPT
- IP65 (NEMA 4X)—The completely sealed, rugged unit can withstand the harshest
environmental conditions
- High speed MPPT for real time power tracking and improved energy harvesting
- Compact size and high power density: 3600W of output power in a box just 420mm x 326mm x 141mm (16.5in x 12.8in x 5.55in)
- Front heatsink keeps the unit cleaner and more efficient over time
- Transformerless operation for highest efficiency—up to 96%
- Reverse polarity protection minimizes chance of damage due to incorrect wiring, only if used
in conjunction with Aurora PVI-WIND-INTERFACE BOX.
- High overload capability—works up to 3600W under most ambient conditions
- True Sine Wave Output
- Anti-islanding Protection
- Certified grid connected operation according to the international standards
- LCD on the front to monitor the main parameters and display kW and kWh
- Wind interface box is optional
Brochure
|
| |
Characteristics |
PVI-6000-OUTD-US-W |
Power Rating Ac (W) |
3600 |
Absolute Max Voltage (Vdc) |
0 to 600 |
Max. Power Tracking Window range (Vdc) |
50 to 580 (360 nominal) |
Power Curve |
Manufacturer special |
Nominal AC Frequency (Hz) |
60 |
| Line Power Factor |
1 |
Maximum AC Line Current (Arms) |
16 |
AC Current Distortion (%) |
<2% THD at rated power
with sinewave voltage |
Max Efficiency (%) |
96 (Euro 95) |
Tare Losses (mW) |
<200 |
Operating Ambient Temperature (°C) |
-25 to +60 |
Enclosure Environmental Rating |
IP65/NEMA 4X |
Relative Humidity |
0-100% condensing |
Elevation |
derated above 6,600ft (2000m) |
Audible Noise (dBA) |
<40 |
Size (height x width depth) (mm) |
420mm x 326mm x 141mm (16.5in x 12.8in x 5.55in) |
Weight (kg) |
13,5 |
|
|