PVI-3600
PVI-6000
Multimode
|
|

The revolutionary switching technology utilized in the Aurora inverter includes state of the art silicon Power Devices such as CoolMOSTM and Gate Bi-polar Transistors (IGBT's) to reduce switching losses.
Aurora has been designed with large de-rating criteria on all critical components, achieving an extremely robust and reliable inverter designed to last for 25 years and to deliver true maximum output power on a continuous basis. With this design concept we achieve peak efficiencies of over 97%. Total current harmonic distortion, on the other hand, is typically less than 1% through the use of high- frequency switching techniques. Another exclusive advantage is Aurora's two source circuit inputs, each with its own MPPT (Max Power Point Tracker) for installations and multiple arrays.
 |
Benefits
- IP65 (NEMA 4) ruggedized, completely sealed unit to stand the harshest environmental conditions
- High speed MPPT for real time power tracking and improved energy harvesting
- Compact size and high power density: 6000W (6000W max) of output power in a box just 740mm x 325mm x 195mm
- Front heatsink keeps the unit cleaner and more efficient over time
- Transformerless operation for highest efficiency: up to 97% (96,5% Euro; 96,5% C.E.C.)
- Reverse polarity protection minimizes chance of damage due to mis-wiring, only if used in conjunction with Aurora PVI-WIND-INTERFACE BOX.
- High overload capability: works up to 6000W under most ambient conditions
- True Sine Wave Output
- Anti-islanding Protection
- Certified grid connected operation according to the International standards
- LCD Display on the front to monitor the main parameters
- Integrated RS-485 serial communication
- WIND INTERFACE BOX is optional
Brochure
|
| |
Characteristics |
PVI-6000-OUTD-US-W |
Power Rating Ac (W) |
6000 |
Absolute Max Voltage (Vdc) |
600 |
Max. Power Tracking Window range (Vdc) |
50 to 580 (360 nominal) |
Input Configuration (Max. Idc = 18 A for each channel) |
Two channel in parallel with common MPPT |
Nominal AC Voltage (Range) (Vms)
|
Single phase 208; 240; 277 (setting required) |
Nominal AC Frequency (Hz) |
60 |
| Line Power Factor |
1 |
Maximum AC Line Current (Arms) |
30 |
AC Current Distortion (%) |
<2% THD at rated power
with finewave voltage |
Max Efficiency (%) |
97 (96,5% C.E.C) |
Tare Losses (mW) |
250 |
Operating Ambient Temperature (°C) |
-25 to +60 |
Enclosure Environmental Rating |
NEMA 4X |
Relative Humidity |
0-100% condensing |
Elevation |
derated above 2.000 m (6,600ft) |
Audible Noise (dBA) |
<50@ 1m |
Size (height x width depth) (mm) |
740 x 325 x 195 |
Weight (kg) |
26 |
|
|